I-view FAC – 500 FingerKey Access Controller DVR Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Panel sterowania I-view FAC – 500 FingerKey Access Controller DVR. I-View FAC – 500 FingerKey Access Controller DVR User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - FAC – 500 FingerKey

FAC – 500 FingerKey Fingerprint Access Controller User Manual Version: V1.1 Doc No.: 20061204

Strona 2

91). FingerKey: Menu key: To open the main menu. Confirm key: To confirm the present operation. Cancel key: To cancel the present operation. Po

Strona 3 - 4.3. Options 66

99 7. Repeat button 8. Zoon in 9. Zoon out 10. Fit to screen 11. Resize 12. Snapshot 13. Copy vi

Strona 4

100Step2: While user selects a date from the calendar, the Timestamp Playback List screen will list all day long AVI playback file for user. User ca

Strona 5 - About this guide

101Chapter 7 Trouble Shooting 1. Cleaning From time to time, the optical platen, the keypad and display window require cleaning. Since working env

Strona 6

102Specification Item \ Model FAC-500 FAC-1500 Plus Storage Capability 500 Fingerprints / 30,000 Records 1500 Fingerprints / 50,000 Records Commu

Strona 7

10 Scrolling up key: To scroll the menu up. Scrolling down key: To scroll the menu down. 2). FingerKey Program (From the CD):

Strona 8 - Certifications and Approvers

11 Exit button: To exit FingerKey program. Login button: To login FingerKey program for operation. 1.3 Function and Feature

Strona 9 - Chapter 1 Product Overview

12Recording: Audio and video recordings can be activated automatically when access starts. Surge Protection: Each video input builds in a 25KV surge

Strona 10 - Optical Fingerprint Sensor

13Chapter 2 Hardware Installation and Software Setting 2.1 Product Application: ◎ SMB Entry Door ◎ Warehouse ◎ Airport ◎ Accounting department ◎

Strona 11

142.2. FingerKey Hardware Installation: 2.2.1. Power Supply Connection FingerKey supports 9-15V DC power supply as input, and can work immediately

Strona 12 - 1.3 Function and Feature

152.2.2. Door Lock Connection FingerKey can support normal-open and normal-closed door lock simultaneously, as long as it is connected with the dif

Strona 13

161). Connecting method for power supply adapter serving for both FingerKey and door lock contemporarily. 1. Matching voltage of lock must be 9 to

Strona 14 - 2.1 Product Application:

172). Connecting method for power supply adapter serving for both FingerKey and door lock contemporarily. 1). Matching voltage of lock is 12V or l

Strona 15

184). High current control of FingerKey and locks connection 1). Matching voltage of lock’s power supply adapter must be accordant with that of lo

Strona 16 - 2.2.2. Door Lock Connection

Table of Contents About this guide ...

Strona 17

192.2.3. Connect with Out-door Switch, Door Magnetism, Doorbell and Warner Door switch is installed in the room, and you can open the door when the

Strona 18

20 GND RS232 R×D RS232 R×D GND RS485 A RS485 B GND DATA 0 DATA 1 +5V Output Door Sensor DNG GND +12V Power Lock COM Lock NO

Strona 19 - Current

212.2.4. Connecting with Controller FingerKey offers the standard Wiegand26 output, and can be connected with most existing Access Controller as co

Strona 20

222.2.5. RS232 and Ethernet Connection FingerKey can connect with PC through RS232 or Ethernet GND GND +12V Power RS2

Strona 21

232.2.6. RS485 Connection FingerKey is connected with RS485 network 2.2.7. Set up FingerKey System IP Address User needs to set up dif

Strona 22

24Step2: Please enter the menu path: Option  Comm Opt  IP Addr Finger 2.1.7 – 1: IP Address NOTE: The first three digits of IP address are co

Strona 23

252.3. Detecting FingerKey Device (EzFingerKey Software Setting) After all FingerKey devices have been installed and connected, user needs to set u

Strona 24

26Step3: Please click the “Change Password” button to open the “Setup Password” dialog. Finger 2.3.1 – 2: Setup Passwo

Strona 25

27Step5: After the login password has been set, user can simply type the user name and password to login the system. Finger

Strona 26

28Step2: Please type a connected FingerKey device’s information in each column and press “Add” button to add device in this management system.

Strona 27

23.3. Enrolling A User ... 37 Chapter 4 FingerKey Device Menu Setup...

Strona 28

29Function Keys To exit this section. To add FingerKey device in this section. To remove a FingerKey device from

Strona 29

30Chapter 3 Basic Operation 3.1. Properly Place The Finger  The correct way is: Place a finger flatware on the sensor surface Place it to t

Strona 30

313.2. Enrolling The First Administrator Setting Outline: 1). Enroll the first administrator in FingerKey device 2). Enroll the first administrat

Strona 31 - Chapter 3 Basic Operation

32(2) Select “Enroll Admin” and press button. (3) Select “Enroll FP” and press button. (4) Please press button to continu

Strona 32

33Step3: Until the screen displays the information as blow Simply place finger 3 times and press button t

Strona 33

34Step2: Press button and type the login name and password to login the system. Finger 3.2 – 1: Login password di

Strona 34 - Function Keys:

35Function Keys: To exit this section. To add FingerKey device in this section. To remove a FingerKey device from this man

Strona 35

36 To add a group name in the system. Step4: Please press “User Manage” ( ) button to set and add enrolling administrator.

Strona 36

37 To add an enrolling user’s fingerprint data in the system. To remove a user from this management system. 3.3. Enrolling A Us

Strona 37

38(4) Please press button to continue. (6) Please use buttons to select UserID number, and press button to continue. Step

Strona 38 - 3.3. Enrolling A User

34.4. Sys Info 84 Chapter 5 EzFingerKey Program Management... 85 5.1. Login and Passw

Strona 39

392). Enroll the user in EzFingerKey program (FingerKey PC software) Step1: Please open the EzFingerKey program from PC (Double click the Ezfinger

Strona 40

40NOTE: For questions about how to add connected FingerKey devices in EzFingerKey system, please refer to section 2.3.2 Setting Up the Fingerprint D

Strona 41

41Section Description: Group NO.: Select a group number from 01 to 10. Description: Type a group name. Function Keys: To exit this section.

Strona 42

42Read Finger Data: Press this button to receive the enrolling user’s fingerprint data from the connected FingerKey device after fill out the inform

Strona 43

43Chapter 4 FingerKey Device Menu Setup 4.1. FingerKey Menu Overview FingerKey Menu Tree User Manage Enroll User Enroll FP Enroll Pwd

Strona 44 - FingerKey Menu Tree

44 Idle Idle Min Lock Power Comm Opt BaudRate Dev Num IP Addr Net Speed

Strona 45

45 Pwd Trig Alarm Delay Auto Test Run All Test FLASH Test LCD Test FP Reader

Strona 46

464.2. User Manage 4.2.1. Enroll User Enroll a user as user authority access. 4.2.1.1. Enroll FP Enroll user by fingerprint Function path: Menu  Us

Strona 47 - 4.2. User Manage

47Note: Please remember which finger has been enrolled for accessing the system next time. Function Keys: Menu Function: Menu option button. Conf

Strona 48

484.2.1.2. Enroll Pwd Enroll user by password Function path: Menu  User Manage  Enroll User  Enroll Pwd Example of Enroll Pwd: (1) Please select

Strona 49

4About this guide Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throu

Strona 50

49(5) Please type the password again to confirm the password. (6) Please press button to complete this password enrollment. (7) To c

Strona 51

50User Verification: User simply uses 0 to 9 buttons to type the enrolled UserID number and press the “OK” button to continue.

Strona 52

514.2.1.3. Enroll FP & Pwd Enroll user by fingerprint and password, so user can either way use fingerprint or password to access the system. Fu

Strona 53

52(5) Please use 0 to 9 buttons to type five digit password, and press button to continue. (6) Please type the password again to

Strona 54

53Cancel Key: To cancel the present operation. Scrolling Up Key: To scroll the menu up. Scrolling Down Key: To scroll the menu down. User Verif

Strona 55

54Please input the password by 0 to 9 number keys. If the verification has been approved, the screen will display as below: If the Ve

Strona 56 - 4.2.2. Enroll Admin

554.2.2. Enroll Admin Enroll a user as administrator authority access. 4.2.2.1. Enroll FP Enroll administrator by fingerprint Function path: Menu 

Strona 57

56 Enroller: Enroller only can access system to enroll new normal user or check system information. (4) Please press button t

Strona 58

57 Scrolling Up Key: To scroll the menu up. Scrolling Down Key: To scroll the menu down. User Verification: User simply presses the enrolle

Strona 59

58(2) Please use buttons to select authority levels and press button to confirm selection and continue. Fin

Strona 60

5included items (including the FAC-500 FingerKey access controller system, written materials and containers) to the location where you purchased the

Strona 61

59(5) Please use 0 to 9 buttons to type five digit password, and press button to continue.

Strona 62

60 Scrolling Up Key: To scroll the menu up. Scrolling Down Key: To scroll the menu down. User Verification: User simply uses 0 to 9 butto

Strona 63

614.2.2.3. Enroll FP & Pwd Enroll user by fingerprint and password, so user can either way use fingerprint or password to access the system. Fu

Strona 64

62(4) Please use 0 to 9 buttons to select UserID number, and press button to continue. (5) Simply place a finger 3 times on the optical a

Strona 65

63(9) To continue enrolling another user by password, please press button or press five times to exit. Note: Please remember whic

Strona 66 - 4.2.3. Delete

64If the Verification is failed, the screen will display as below: OR (2) User password to access the system: User simply uses

Strona 67 - 4.3. Options

654.2.3. Delete This selection is to delete an enrolled user from system. Function path: Menu  User Manage  Delete Example of Delete function: (1

Strona 68

664.3. Options 4.3.1. System Opt (System Option) 4.3.1.1 Date Time This function is to setup FingerKey’s date and time. Function Path: Menu  Option

Strona 69

674.3.1.2 Language This function provides user to select different display languages. Function Path: Menu  Options  System Opt  Language Example

Strona 70

684.3.1.3 Fmt (Display Format) This function is to change the date and time’s display format. Function Path: Menu  Options  System Opt  Fmt Exam

Strona 71

6the accompanying documentation and that CD-ROM diskettes are free from any defects for a period of 90 days from the date of purchase (limited warra

Strona 72

694.3.1.4 Adv Option (System Advanced Option) Function Path: Menu  Options  System Opt  Adv Option Note: To access Adv Option functions, user

Strona 73

701:1 Thr: 1:1 Threshold Levels, ID+ Fingerprint identification and degree of register template matching. Function Keys: Confirm Key: To confirm t

Strona 74

71Function Keys: Confirm Key: To confirm the present operation. Cancel Key: To cancel the present operation. Selection Keys: To select the select

Strona 75

722.2.7 Set up FingerKey System IP Address on page 23. Net Speed: Network speed, the default network speed is 10M-F. Ethernet: To set if open Ethern

Strona 76

73attendance logs, while the setting number has been reached, the system will trigger the alarm. The number range of counting supervisor logs is fro

Strona 77

74 Setting Time Plane number (2) Please select day and time to set up. Setting number one time plan accessing schedule Function Ke

Strona 78

752). Select a function to set up user. Function Descriptions: Belong to GPR: To divide a registered user in a group. Use GRP TPs: To set if use

Strona 79

764.3.5.3. GRP TP Define Define Group Time Plan, This function is to configure and group the setting schedule. Function Path: Menu  Options  Acces

Strona 80

774.3.5.4. Access Comb Access combination is the direct representation of access controlling. For example, if user wants that all registered users c

Strona 81

782). Use number keys to set groups number in Comb 1, and press button to continue. 3). After all combs setting has been done, pleas

Strona 82

7download or otherwise export or re-export the Witness system or related software or any underlying information or technology except in full complia

Strona 83

79 Use buttons to select Luck function and press button to set up. Function Keys: Confirm Key: To confirm the present operatio

Strona 84

804.3.5.7. DSen Mode Door Sensor Mode, there are three selections of this section. NO: Normally Open, the contacts of a switch or relay are normal

Strona 85 - 4.4. Sys Info

81Function Descriptions: Duress FP: To enroll or disable existing registered fingerprints. Help Key: To enable or disable the help key. 1:1 Trig

Strona 86

82 New Enrollment: To enroll a new duress fingerprint for an existing registered user. 1). Select an existing registered UserID by numeric buttons

Strona 87

83 Undef DuressFP: To disable a duress fingerprint from the system.  Undef All: To disable all of duress fingerprints from the system. Fu

Strona 88

844.4. Sys Info 1). User Cnt: The amount of registered users. 2). FP Cnt: The amount of registered fingerprints. 3). Att Log: The amount of the u

Strona 89

85Chapter 5 EzFingerKey Program Management EzFingerKey is a PC program to easily manager registered user and enrollment data of a FingerKey device.

Strona 90 - 5.3. Group

862). User name and password setting: Please click the “Change Password” button to open the “Setup Password” dialog, and type the user name and pas

Strona 91 - 5.4. User Management

875.2. Fingerprint Device Setting This function is to set up a FingerKey device information and connect with each other. Please click the “Setup Fi

Strona 92

88 IP Address: The connected FingerKey device’s IP address. The IP Address need to be same as connected FingerKey device’s IP address. To che

Strona 93 - 5.5. Time Zone

8Chapter 1 Product Overview 1.1 Unpacking 1). One screwdriver 2). One FingerKey Access Control Machine 3). One CD (FingerKey software) 4). One Fi

Strona 94 - 5.6. Backup Data

895.3. Group This function is to set up group for easy management. Please press “Group” ( ) button to add group name or department name for e

Strona 95 - 6.1. Setup I/O Port

905.4. User Management Please press “User Manage” ( ) button to set and add enrolling users. Finger 5.4.-1: User Ma

Strona 96

91Function Keys: To exit this section. To add an enrolling user’s fingerprint data in the system. To remove a user

Strona 97

925.5. Time Zone This function is to schedule registered users’ FingerKey system access time. To start this function, please simply click the “Time

Strona 98 - 6.2. View Log

935.6. Backup Data This function provides user to backup all of the registered users’ data from this EzFingerKey management system. To start this fu

Strona 99

94Chapter 6 Functions with Witness DVR Program Witness DVR program can support maximum 16 FingerKey devices. With Witness DVR program support, user

Strona 100

952). Click the “Set up Access Controller” button to enter the Access Controller setting dialog. “Set up Access Controller” Function Description:

Strona 101

96 Enable sound alarm: To enable about if the Witness will start sounding alarm with the “Select sound alarm” setting while the event has been tri

Strona 102 - Chapter 7 Trouble Shooting

976.2. View Log To see the FingerLog file, simply press “View Log” ( ) button on the bottom of the Witness program to open the log

Strona 103 - Specification

986.3. POS Playback – EzPosPlayback EzPosPlayback provides users to easily search specific video file by time, preset keywords and keywords searchi

Komentarze do niniejszej Instrukcji

Brak uwag